How compressed air transmits force — the gas laws and pressure scales, the air-treatment chain, dryers and FRL conditioning, valves and distribution, cold-weather freeze prevention, and troubleshooting.
What the exam tests here
The gas laws (Boyle / Charles / Ideal — use absolute units); absolute vs gauge vs vacuum pressure; the air-treatment chain in order (intake filter → intercooler → aftercooler → receiver → dryer → filter → regulator → lubricator) and dew point; dryer types and the FRL; how pneumatic valves differ from hydraulic ones; distribution layouts and air-drops; cold-weather freeze prevention; and cylinder and valve troubleshooting. Many components mirror the hydraulics chapter — the gas laws and air treatment are what's unique here.
Pneumatic systems transmit force with compressible air drawn from the atmosphere. Pascal's Law, Bernoulli's principle and conservation of energy all apply, as they do in hydraulics.
Exam tip
Pneumatics use compressible air from the atmosphere — unlike hydraulics, the working fluid changes volume, which is why storage, drying and pressure control matter so much.
Gauge to absolute pressure
psia = psig + 14.7
Gauge pressure ignores the atmosphere; add 14.7 psi at sea level to get absolute
Maximum vacuum force
Max vacuum force = 14.7 psi × the cup or pad area
A perfect vacuum is 0 psia, so the atmosphere can push with at most 14.7 psi
Exam tip
psia = psig + 14.7. A perfect vacuum is 0 psia, which is why a vacuum can pull with no more than 1 bar (14.7 psi).
Vacuum cup area
Cup area = (load × safety factor) ÷ vacuum in psi
Vacuum in psi = in Hg ÷ 2.04. A 40 lb load with a safety factor of 3 needs 120 lb; at 24 in Hg (11.8 psi) that is 120 ÷ 11.8 ≈ 10.2 in² of cup.
| Law | Held constant | Relationship |
|---|---|---|
| Boyle's | Temperature | P₁V₁ = P₂V₂ (P inversely proportional to V) |
| Charles' | Pressure | V₁ ÷ T₁ = V₂ ÷ T₂ (V proportional to absolute T) |
| Gay-Lussac | Volume | P₁ ÷ T₁ = P₂ ÷ T₂ (P proportional to absolute T) |
| Ideal (combined) | — | P₁V₁ ÷ T₁ = P₂V₂ ÷ T₂ |
Boyle's Law
P₁V₁ = P₂V₂
Constant temperature — pressure inversely proportional to volume
Charles' / Gay-Lussac's Law
V₁ ÷ T₁ = V₂ ÷ T₂ (constant P)
P₁ ÷ T₁ = P₂ ÷ T₂ (constant V)
Volume and pressure each proportional to absolute temperature
Ideal Gas Law
P₁V₁ ÷ T₁ = P₂V₂ ÷ T₂
Boyle and Charles combined
Vacuum pumps remove air rather than compress it. Rough maximum ratings:
| Vacuum pump | Max (″ Hg) |
|---|---|
| Rotary vane, multi-stage | 29.5 |
| Piston, multi-stage | 28.5 |
| Screw | 28.5 |
| Oil vane | 28 |
| Dry vane | 26 |
| Lobe | 15 |
| Centrifugal | 7 |
Watch out
Always use absolute pressure and absolute temperature (psia, Kelvin or Rankine) in every gas-law calculation — gauge pressure or °C / °F gives a wrong answer.
A venturi vacuum generator (ejector) has no moving parts: plant air speeds up through a nozzle, its pressure falls (Bernoulli), and the suction port beside the jet draws air out of the cups. It uses air the whole time it runs and needs clean, dry, oil-free air. With nothing inside to wear, a slow loss of vacuum (supply pressure right, lines tight) means a clogged exhaust silencer or suction filter: clean or replace them.
Milky oil in an oil-sealed vane vacuum pump means water: vapour drawn from the process condenses into the oil as the pump compresses it. Wet oil can't seal the vanes, so the vacuum falls off. Change the oil, then run with the gas ballast open: it lets a little air into the compression stage so the vapour leaves with the exhaust instead of condensing.
Free air carries dirt, moisture and varying heat, so treat it before use: filter → cool → remove moisture / oil → store. Full chain: intake filter → intercooler → aftercooler → receiver → dryer → filter → regulator → lubricator.
Exam tip
Order matters: cool the air before storing it, and store it before drying it — aftercooler → receiver → dryer → filter → regulator → lubricator.
| Air dryer | How it works | Note |
|---|---|---|
| Deliquescent | Chemical desiccant absorbs moisture | Desiccant is consumed and replaced |
| Regenerative desiccant | Silica gel / alumina / molecular sieve, two towers | ~75 % heat / 25 % cool cycle |
| Refrigeration | Chill → condense → reheat | — |
| Membrane | Passes water-vapour molecules out | No moving parts, non-electric — good for hazardous areas |
Air dryer symbol
Air dryer
Two lines across the top and bottom corners
Air preparation symbols
FRL unit (filter, regulator, lubricator)
Dash-dot box around a filter with drain, an adjustable regulator with its gauge, and a lubricator
Filter-separator
Filter element plus a bowl line across the bottom corner, with a drain
Water separator, automatic drain
Bowl with a small V inside: the automatic drain
Lubricator
Short line down from the top corner: oil drips in
Exam tip
FRL = Filter-Regulator-Lubricator, modular so any one unit is removable without disturbing the others; the lubricator meters only a few drips per minute — wrong or excess oil forms carbon deposits and leaks.
Exam tip
Pneumatic DCVs exhaust spent air to atmosphere — the key difference from hydraulic valves; because air is fast, use manual or pilot valves (not solenoids) for controlled creep-to-full speed.
Pneumatic valve symbols
5/2 valve (air)
1 supply, 2 and 4 outlets, 3 and 5 exhausts
5/3 valve, all ports sealed
All ports blocked
5/3 valve, outlets to exhaust
2 and 4 to exhaust, supply blocked
5/3 valve, supply to outlets
Supply to 2 and 4, exhausts blocked
Shuttle valve (OR)
Ball between two seats: two inlets, one outlet
| Layout | Character |
|---|---|
| Grid (dead-end) | Cheapest; the main tapers down — risks air starvation at the far end under heavy demand |
| Decentralized | Several grids, each with its own compressor — shorter lines, more uniform |
| Loop | Compressors around a continuous ring — parallel supply from either direction; the preferred system |
Exam tip
Take air-drops from the top of the main (a tee that rises then drops) so moisture runs past to a water leg — and slope every line 2.5–5 cm per 3 m to a drain.
Watch out
Thaw a frozen valve gradually — never with an oxyacetylene flame, because rapid heat cracks the valve body.
| Problem | Possible cause | Solution |
|---|---|---|
| Cylinder drifting | Piston seal leaking; operating valve leaking; connecting lines leaking | Replace the piston seal; repair/replace the valve; tighten or repair the lines |
| Cylinder sticking or binding | Rod packing overtightened; cylinder misaligned; defective seals; low pilot pressure | Loosen/replace the packing; align the cylinder; replace seals; adjust pilot pressure |
| Cylinder body seal leaking | Tie rods loose; excessive pressure at the cylinder; seal pinched or extruded | Retorque the tie rods; adjust pressure; replace the body seal |
| Rod gland seal leaking | Seal deteriorating | Replace the seal |
| Extends faster but retracts slower than normal | Rod seal leaking: on extension it gives the exhausting rod end a second way out; on retraction it lets the supply air escape | Replace the rod seal |
| Cylinder slams into one end after a reseal; that end's cushion needle has no effect | Cushion seal damaged, left out or fitted backward: it traps the exhaust air so it can only bleed out past the needle, and it seals one way only | Strip that end; fit a good cushion seal the right way round |
| Valve blows to exhaust when NOT actuated | Inlet poppet not sealing | Repair/replace the poppet |
| Valve blows to exhaust when actuated | Faulty valve seals; faulty valve-to-base gasket; damaged spool | Replace seals; replace gasket; repair/replace spool |
| Pilot section blows to exhaust | Pilot cover loose; poppet not sealing | Tighten the cover; repair/replace the poppet |
| Poppet chattering | Supply pressure too low; pilot/signal pressure too low | Adjust the supply; adjust the pilot or signal pressure |
Exam tip
Not actuated and blowing = inlet poppet. Actuated and blowing = seals, gasket or spool. Chatter = low supply or pilot pressure. Binding = packing, alignment, seals or pilot pressure.
The full study guide covers every block of the 433A Industrial Millwright exam, with practice questions and a timed mock exam.